Skip to main content

Fly Buffer Plus Firmware Flashing

Applicable Versions

This document applies to devices with firmware versions lower than v2.0.0. If your firmware version has reached or exceeded this version, please refer to the Firmware Update document and update directly via the web tool without entering DFU mode.

Check Firmware Version​

Through the Web Tool, you can view the current firmware version number after connecting the device.

Enter DFU Flashing Mode​

Power Off

Before starting, fully shut down the printer and disconnect the power supply. Do not plug or unplug cables, organize wiring, or touch terminals while the device is powered on.

You can put the device into flashing mode using any of the following methods:

  • Method 1:

    1. Connect the device to your computer using a Type-C data cable.
    2. Press and hold the BOOT button on the device, briefly press the RESET button, then release BOOT.
  • Method 2:

    1. Press and hold the BOOT button on the device.
    2. Connect the Type-C data cable to both the device and the computer, then release the BOOT button.
Loading...

Flashing Methods​

Power-off operation

Before connecting or reconnecting the USB cable, completely turn off the printer and disconnect all other power supplies. Do not let the tool board be powered simultaneously through the printer power supply and the USB interface.

USB connection compatibility

The USB interfaces on some computers may cause unstable flashing due to driver or signal compatibility issues. If the connection fails, try using a different USB interface on the computer or use a reliable-quality USB dock; when the error shown below appears, also check the USB connection and driver first.

Loading...
  1. Download and install SetupSTM32CubeProgrammer and the STM32 DFU driver from the auxiliary software download page.
  2. Save the firmware downloaded on this page to a location on your computer that is easy to find.
Windows file extension display

Windows may hide file extensions. In File Explorer, check "File name extensions" to confirm that the firmware is still .bin or .hex, and do not change the file extension.

  1. Confirm that the device has entered DFU flashing mode according to the product tutorial, then connect it to the computer using a USB cable that supports data transfer.
  2. Open STM32CubeProgrammer, select USB mode, refresh the device list, and connect.
Loading...
  1. If no error pop-up appears, the connection is successful.
Loading...
  1. Click the download icon on the left, and check the flashing options as shown in the figure below.
Loading...
  1. Click Browse and select the firmware to be flashed.
Loading...
  1. When flashing .bin firmware, set Start address to 0x08000000; when using .hex firmware, keep the address included in the file.
Loading...
  1. Click Start automatic mode to begin flashing.
Loading...
  1. When the success prompt appears, the firmware flashing is complete.
Loading...
Note

Do not disconnect the Type-C connection during the flashing process, as this may cause the flashing to fail.

Next Steps​

After the BOOT firmware flashing is completed, the device supports direct main firmware updates through the web tool without needing to enter DFU mode again.

Please refer to the Firmware Update document to complete the main firmware update.